0.6/1kv Cu Conductor PVC/XLPE Insulated Aluminum/Steel Tape Armour Power Cable

Model NO.: Power Cable
Wire Core Material: Copper or Aluminium or Aluminium Alloy
Certification: ISO, CCC, CE, BV
Model: Yjv, Yjv22, Yjv32, Zr-Yjv
Brand: Rmjt
Standard: GB/T 12706-2008, IEC 60502-2005
Core Number: 1, 2, 3, 4, 5, 3+1, 3+2, 4+1
Screen: Copper Tape/Copper Wire/Unscreened
Sheath Colour: Black, Red, Blue, Other as Per Requirement
Flame Retardant: Available, as Per Customer&Prime′s Requirement
Armor Material: Steel Tape or Galvanized Sreel Wire
Related Voltage: 0.6/1kv; 8.7/15kv; 12/20kv; 21/35kv; 26/35kv
Popular Size: 95mm 120mm 150mm
Business Type: Factory
OEM: Yes
Trademark: RMjT
Transport Package: Wooden Drum &Wooden Steel Drum
Specification: 0.5mm2~800mm2
Origin: China
HS Code: 8544492100
Model NO.: Power Cable
Wire Core Material: Copper or Aluminium or Aluminium Alloy
Certification: ISO, CCC, CE, BV
Model: Yjv, Yjv22, Yjv32, Zr-Yjv
Brand: Rmjt
Standard: GB/T 12706-2008, IEC 60502-2005
Core Number: 1, 2, 3, 4, 5, 3+1, 3+2, 4+1
Screen: Copper Tape/Copper Wire/Unscreened
Sheath Colour: Black, Red, Blue, Other as Per Requirement
Flame Retardant: Available, as Per Customer&Prime′s Requirement
Armor Material: Steel Tape or Galvanized Sreel Wire
Related Voltage: 0.6/1kv; 8.7/15kv; 12/20kv; 21/35kv; 26/35kv
Popular Size: 95mm 120mm 150mm
Business Type: Factory
OEM: Yes
Trademark: RMjT
Transport Package: Wooden Drum &Wooden Steel Drum
Specification: 0.5mm2~800mm2
Origin: China
HS Code: 8544492100
Copper/Aluminum Conductor XLPE Insulated PVC Sheathed Power Cable
0.6/1kv Cu Conductor PVC/XLPE Insulated Aluminum/Steel Tape Armour Power Cable

Standard:

IEC60502, BS6346, VDE, AS/NZS, UL, etc 

The Rated Voltage(kv):

1st  class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

Application:

XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.

TYPE

NAME

Main Application

CU core

AL core

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

Number of cores:

1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.

Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Features:

1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground. 

Specification
0.6/1kv Cu Conductor PVC/XLPE Insulated Aluminum/Steel Tape Armour Power Cable

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1x4 2.3 0.7 1 0.8 1.8 10.9
1x6 2.8 0.7 1 0.8 1.8 11.4
1x10 3.6 0.7 1 0.8 1.8 12.2
1x16 4.5 0.7 1 0.8 1.8 13.1
1x25 5.6 0.9 1 0.8 1.8 14.6
1x35 6.7 0.9 1 1.25 1.8 16.6
1x50 8 1 1 1.25 1.8 18.1
1x70 9.4 1.1 1 1.25 1.8 19.7
1x95 11 1.1 1 1.6 1.8 22
1x120 12.4 1.2 1 1.6 1.8 23.6
1x150 13.8 1.4 1 1.6 1.8 25.4
1x185 15.3 1.6 1 1.6 1.8 27.4
1x240 17.5 1.7 1 1.6 1.9 29.9
1x300 19.5 1.8 1 2 2 33.1
1x400 22.6 2 1.2 2 2.2 37.3
1x500 25.2 2.2 1.2 2 2.3 40.5
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2x1.5 1.4 0.7 1 0.8 1.8 12.8
2x2.5 1.8 0.7 1 0.8 1.8 13.6
2x4 2.3 0.7 1 0.8 1.8 14.6
2x6 2.8 0.7 1 1.25 1.8 16.5
2x10 3.6 0.7 1 1.25 1.8 18.1
2x16 4.5 0.7 1 1.25 1.8 19.9
2x25 5.6 0.9 1 1.6 1.8 23.6
2x35 6.7 0.9 1 1.6 1.8 25.8
2x50 8 1 1 1.6 1.9 29
2x70 9.4 1.1 1 2 2 .3 3.2
2x95 11 1.1 1.2 2.1 3 7.1
2x120 12.4 1.2 1.2 2 2.3 40.5
2x150 13.8 1.4 1.2 2.5 2.4 45.4
2x185 15.3 1.6 1.4 2.5 20.6 49.9
2x240 17.5 1.7 1.4 2.5 20.7 55.1
2x300 19.5 1.8 1.6 2.5 20.9 60.2
2x400 22.6 2 1.6 2.5 30.1 67.7
Â